You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 103 No. 3, September 1971 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL ARTICLES
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Anastomotic False Aneurysms

John P. West, MD; Conrad Lattes, MD; W. Graham Knox, MD

AMA Arch Surg. 1971;103(3):348-350.


Abstract

An analysis is made of 16 false aneurysms occurring after arterial grafting in 14 patients. Eight aneurysms were in the abdomen; six were at anastomotic sites on femoral arteries. One was in the popliteal artery and one at an arteriotomy site in a femoral graft. None was due to infection. Eleven seemed due to weakness of the arterial wall. In five the problem was the lack of strength (silk) or the lack of proper tying (polyethylene) of the suture material. Eleven of the 16 did not present until two years or more after insertion.



Author Affiliations

New York

From the Department of Surgery, St. Luke's Hospital Center, New York.


Footnotes

Accepted for publication March 29, 1971.

Reprint requests to 1107 Fifth Ave, New York 10028 (Dr. West).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Titanium Dioxide Particle-induced Alkaline Degradation of Poly(ethylene Terephthalate): Application to Medical Textiles
Rahman and East
Textile Research Journal 2009;79:728-736.
ABSTRACT  

A Unique Presentation of an Anastomotic Pseudoaneurysm-Case Report
Schweitzer and Matas
VASC ENDOVASCULAR SURG 1991;25:131-135.
ABSTRACT  

Intermittent Aortic-Graft Obstruction Secondary to Anastomotic Aneurysms
McCabe et al.
Arch Surg 1981;116:1206-1208.
ABSTRACT  

Pseudoaneurysm Following Axillo-Femoral By-Pass: Unusual Presentation
Graziano and Mulet
VASC ENDOVASCULAR SURG 1975;9:195-199.
 





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1971 American Medical Association. All Rights Reserved.