You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 108 No. 6, June 1974 TABLE OF CONTENTS
  Archives
  •  Online Features
  PAPERS READ BEFORE THE ANNUAL MEETING OF THE SOUTHERN CALIFORNIA CHAPTER OF THE AMERICAN COLLEGE OF SURGEONS, PALM SPRINGS, CALIF, JAN 18-20, 1974
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (12)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

The Placement of Vena Cava Umbrella Filters

The Value of Phlebography

Douglas McConnell, MD; Donald Mulder, MD; Gerald Buckberg, MD

AMA Arch Surg. 1974;108(6):789-791.


Abstract

Vena cava umbrella filters, employed to treat pulmonary embolism, are usually positioned at the level of the inferior pole of the right kidney as determined from intravenous pyelography (IVP).

Using inferior cavography to define caval anatomy, we found anomalies in two of ten patients (single left inferior vena cava, double inferior vena cava). One patient, in whom an umbrella was previously placed at the level of the inferior pole of the right kidney, developed recurrent pulmonary emboli from the cul-de-sac between the occluded umbrella and the right renal vein; a second umbrella was placed. In another patient, postplacement vena cavography identified umbrella obstruction of the right renal vein; repositioning with a second umbrella was successful.

Combined vena cavography and umbrella placement allows (1) visualization of inferior vena cava, including anomalies; (2) precise placement of umbrella filter; (3) occasional detection of source of emboli; and (4) confirmation of diagnosis of pulmonary embolus.



Author Affiliations

Los Angeles

From the Division of Thoracic Surgery, UCLA Medical Center, Los Angeles.


Footnotes

Accepted for publication Feb 13, 1974.

Read before the annual meeting of the Southern California Chapter of the American College of Surgeons, Palm Springs, Calif, Jan 18, 1974.

Reprint requests to Division of Thoracic Surgery, UCLA Medical Center, Los Angeles, CA 90024 (Dr. Buckberg).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Requirements for a Method of Transvenous Inferior Vena Cava Interruption
Hunter et al.
Arch Surg 1980;115:1324-1330.
ABSTRACT  

Avoiding Renal Vein Entry When Implanting the Mobin-Uddin Vena Cava Umbrella Filter
Edoga and Widmann
Arch Surg 1979;114:752-753.
ABSTRACT  

Comparison of Caval Filters in the Management of Venous Thromboembolism
Wingerd et al.
Arch Surg 1978;113:1264-1271.
ABSTRACT  

Treatment and Prevention of Mobin-Uddin Umbrella Misplacement
Fee et al.
Arch Surg 1978;113:331-332.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1974 American Medical Association. All Rights Reserved.