You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 111 No. 2, February 1976 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL ARTICLES
 This Article
 •References
 •Full text PDF
 •Correction
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (44)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Systemic and Local Complications Following Low-Friction Arthroplasty of the Hip Joint

A Study of 800 Consecutive Operations

Nas S. Eftekhar, MD; Howard A. Kiernan, Jr, MD; Frank E. Stinchfield, MD

Arch Surg. 1976;111(2):150-155.


Abstract

• At the New York Orthopaedic Hospital, a study was made of postoperative complications in 800 consecutive total hip replacements of the Charnley low-friction arthroplasty type. Specially designed records made it possible to document and include all systemic and local complications of this procedure. While the rate of postoperative infection was low (less than 1%), thromboembolism and deep-vein thrombosis incidence was high despite the introduction of a prophylactic anticoagulation regimen. There were no deaths during or immediately after surgery, but six occurred within the first six weeks postoperatively. Two were due to a massive pulmonary embolus (proved at autopsy), two to myocardial infarction (clinical diagnosis), and one to a perforated cecum (proved at autopsy). The incidence of mechanical and technical failures in our series was relatively low and quite comparable with results reported by others.

(Arch Surg 111:150-155, 1976)



Author Affiliations

From the Department of Orthopaedic Surgery, College of Physicians and Surgeons, Columbia University, and the New York Orthopaedic Hospital, Columbia-Presbyterian Medical Center, New York.


Footnotes

Accepted for publication Sept 3, 1975.

Reprint requests to 161 Fort Washington Ave, New York, NY 10032 (Dr Eftekhar).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Obturator Nerve Palsy due to Fixation of an Acetabular Reinforcement Ring with Transacetabular Screws. A Case Report
FRICKER et al.
JBJS 1997;79:444-6.
FULL TEXT  

Transacetabular Herniation of Small Bowel and Right Adnexa: An Unusual Complication of Hip Arthroplasty
Gore et al.
JAMA 1983;250:2349-2350.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1976 American Medical Association. All Rights Reserved.