Operative CholangiographyNew Cholangiogram Catheter Clamp and Improved Technique
James Borge, MD
Arch Surg. 1977;112(3):340-342.
Abstract
We present 225 cases of routine operative cholangiography, utilizing a new squeeze-locking, split-loop clamp to secure the catheter inside the cystic duct plus an x-ray film technique using two different dye concentrations. No surgical or procedural difficulty was experienced in any of the 225 cases. Additional operating time for the procedure averaged under five minutes, with only one inconclusive x-ray film study. These results suggest that the new catheter clamp and the two-film technique provide a mechanical simplification of the procedure and that many of the causes of inconclusive x-ray film study have been eliminated.
(Arch Surg 112:340-342, 1977)
Author Affiliations
From the Department of Surgery, Queen of the Valley Hospital, Napa, Calif, and the Vallejo General Hospital, Vallejo, Calif.
Footnotes
Accepted for publication Oct 22, 1976.
Read before the East Bay Surgical Society, Carmel, Calif, May 8, 1976.
Reprint requests to 980 Trancas St, Napa, CA 94558 (Dr Borge).