Extra-anatomical bypass of iliac vein obstruction: use of a synthetic (expanded polytetrafluoroethylene [Goretex]) graft
A. W. Clowes
A long synthetic graft polytetrafluoroethylene was used to provide an
extra-anatomic bypass of an iliac vein obstruction secondary to recurrent
thrombophlebitis. The graft has remained patent during the 12-month period
of observation. A distal, previously placed arteriovenous fistula in this
circumstance was important.