Effect of Intracorporeal-Extracorporeal Instrument Length Ratio on Endoscopic Task Performance and Surgeon Movements
Tarek A. Emam, MB, BCh, MCh;
George B. Hanna, MB, BCh, FRCS(Edin), PhD;
Chris Kimber, FRACS, MBBS, FRACS;
Peta Dunkley, MB, BCh, FRCS;
Alfred Cuschieri, MD, ChM, FRCS(Edin), FRSE
Arch Surg. 2000;135:62-65.
Hypothesis Better endoscopic task performance and more ergonomic movements of a surgeon's dominant upper limb can be achieved within a certain range of intracorporeal-extracorporeal instrument length ratio.
Design Investigating the effect of 3 intracorporeal-extracorporeal instrument length ratios (240:120 mm, level 1; 180:180 mm, level 2; and 120:240 mm, level 3) on efficiency and quality of a standardized endoscopic task (intracorporeal surgeon's knot). Ten surgeons tied 360 knots inside a trainer in a random sequence. Task efficiency was measured by the execution time, which was recorded for each knot. Task quality was measured by the knot quality score, derived from the force-extension curves obtained by distraction of each knot in a tensiometer. Motion analysis parameters were obtained at the elbow and shoulder joints using a 3-dimensional motion analysis system (Kinemetrix Model 5.0-3D/3MBM; Medical Research Ltd, Leeds, England). The Kruskal-Wallis and Mann-Whitney tests were used for analysis.
Results The level 3 ratio had the lowest knot quality score (P = .07) and longest execution time (P<.05). The range of movement at the elbow was significantly greater with the level 3 ratio than with the level 1 ratio (P<.05). The level 3 ratio also resulted in the widest range of movement at the shoulder (P<.05 for level 2 vs 3; P = .06 for level 1 vs 3). The median angular velocity was 329.5°/s, 360°/s, and 530°/s for levels 1, 2, and 3, respectively (P = .10).
Conclusions Intracorporeal-extracorporeal instrument length ratio below 1.0 degrades task performance and is associated with a wider range of movement at the elbow and shoulder and a higher angular velocity at the shoulder.
From the Department of Surgery and Surgical Skills Unit, Ninewells Hospital and Medical School, Dundee, Scotland.
CiteULike Connotea Del.icio.us Digg Reddit Technorati Twitter
What's this?
RELATED ARTICLES
Archives of Surgery Reader's Choice: Continuing Medical Education
Arch Surg. 2000;135(1):109-110.
FULL TEXT
Invited Critique: Effect of Intracorporeal-Extracorporeal Instrument Length Ratio on Endoscopic Task Performance and Surgeon Movements
Ramon Berguer
Arch Surg. 2000;135(1):66.
EXTRACT
| FULL TEXT
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
Minimally Invasive Myocardial Revascularization
Falk and Mohr
Card Surg Adult 2008;3:697-710.
FULL TEXT
Methodological Infrastructure in Surgical Ergonomics: A Review of Tasks, Models, and Measurement Systems
Lee et al.
SURG INNOV 2007;14:153-167.
ABSTRACT
Ergonomics of Hand-Assisted Laparoscopic Surgery
Hanna et al.
SURG INNOV 2001;8:92-95.
ABSTRACT
Computer-enhanced ""robotic"" cardiac surgery: Experience in 148 patients
Mohr et al.
J. Thorac. Cardiovasc. Surg. 2001;121:842-853.
ABSTRACT
| FULL TEXT
|