You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 135 No. 1, January 2000 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Citing articles on Web of Science (21)
 •Contact me when this article is cited
 Related Content
 •Related articles
 •Similar articles in this journal
 Topic Collections
 •Surgery
 •Surgical Interventions
 •Endoscopy/ Minimally Invasive Surgery
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Effect of Intracorporeal-Extracorporeal Instrument Length Ratio on Endoscopic Task Performance and Surgeon Movements

Tarek A. Emam, MB, BCh, MCh; George B. Hanna, MB, BCh, FRCS(Edin), PhD; Chris Kimber, FRACS, MBBS, FRACS; Peta Dunkley, MB, BCh, FRCS; Alfred Cuschieri, MD, ChM, FRCS(Edin), FRSE

Arch Surg. 2000;135:62-65.

Hypothesis  Better endoscopic task performance and more ergonomic movements of a surgeon's dominant upper limb can be achieved within a certain range of intracorporeal-extracorporeal instrument length ratio.

Design  Investigating the effect of 3 intracorporeal-extracorporeal instrument length ratios (240:120 mm, level 1; 180:180 mm, level 2; and 120:240 mm, level 3) on efficiency and quality of a standardized endoscopic task (intracorporeal surgeon's knot). Ten surgeons tied 360 knots inside a trainer in a random sequence. Task efficiency was measured by the execution time, which was recorded for each knot. Task quality was measured by the knot quality score, derived from the force-extension curves obtained by distraction of each knot in a tensiometer. Motion analysis parameters were obtained at the elbow and shoulder joints using a 3-dimensional motion analysis system (Kinemetrix Model 5.0-3D/3MBM; Medical Research Ltd, Leeds, England). The Kruskal-Wallis and Mann-Whitney tests were used for analysis.

Results  The level 3 ratio had the lowest knot quality score (P = .07) and longest execution time (P<.05). The range of movement at the elbow was significantly greater with the level 3 ratio than with the level 1 ratio (P<.05). The level 3 ratio also resulted in the widest range of movement at the shoulder (P<.05 for level 2 vs 3; P = .06 for level 1 vs 3). The median angular velocity was 329.5°/s, 360°/s, and 530°/s for levels 1, 2, and 3, respectively (P = .10).

Conclusions  Intracorporeal-extracorporeal instrument length ratio below 1.0 degrades task performance and is associated with a wider range of movement at the elbow and shoulder and a higher angular velocity at the shoulder.


From the Department of Surgery and Surgical Skills Unit, Ninewells Hospital and Medical School, Dundee, Scotland.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

RELATED ARTICLES

Archives of Surgery Reader's Choice: Continuing Medical Education
Arch Surg. 2000;135(1):109-110.
FULL TEXT  

Invited Critique: Effect of Intracorporeal-Extracorporeal Instrument Length Ratio on Endoscopic Task Performance and Surgeon Movements
Ramon Berguer
Arch Surg. 2000;135(1):66.
EXTRACT | FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Minimally Invasive Myocardial Revascularization
Falk and Mohr
Card Surg Adult 2008;3:697-710.
FULL TEXT  

Methodological Infrastructure in Surgical Ergonomics: A Review of Tasks, Models, and Measurement Systems
Lee et al.
SURG INNOV 2007;14:153-167.
ABSTRACT  

Ergonomics of Hand-Assisted Laparoscopic Surgery
Hanna et al.
SURG INNOV 2001;8:92-95.
ABSTRACT  

Computer-enhanced ""robotic"" cardiac surgery: Experience in 148 patients
Mohr et al.
J. Thorac. Cardiovasc. Surg. 2001;121:842-853.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2000 American Medical Association. All Rights Reserved.