Glove Leakage Rates as a Function of Latex Content and Brand

Caveat Emptor

Carlene A. Muto, MD, MS; Maria G. Sistrom, MSN; Barbara A. Strain, MA; Barry M. Farr, MD, MSc

Arch Surg. 2000;135:982-985.

Hypothesis  That water leakage rates and protection against blood-borne pathogens should not vary as a function of latex content among Food and Drug Administration–approved gloves, allowing avoidance of unnecessary latex exposure.

Design and Methods  Eighteen different glove types were purchased and tested using the American Society for Testing Methods Standard Test for Detecting Holes in medical gloves, which involves mounting the glove on a plastic tube, pouring a liter of tap water into the glove, and visually inspecting the glove initially and after 2 minutes. Half of the gloves were tested straight from the package and half after a standardized manipulation.

Setting  A university hospital.

Results  Eleven sterile glove types (5 high latex content, 4 low latex content, and 2 nonlatex content), and 7 nonsterile examination glove types (2 high latex content, 2 low latex content, and 3 nonlatex content) were tested (total tested, 3720 gloves). Leakage rates were greater for examination than for surgical gloves (relative risk [RR], 1.41, 95% confidence interval [CI], 1.01-1.96), for manipulated than for unused gloves (RR, 2.89, 5% CI, 1.98-4.22), and for low latex content surgical gloves (RR, 2.58, 95% CI, 1.35-4.92) or nonlatex content surgical gloves (RR, 4.93, 95% CI, 2.35-10.32) than for high latex content surgical gloves. Significant differences were observed among low latex content surgical gloves (P≤.001) and all types of examination gloves (P = .0015) especially after the standardized manipulation (leakage rates ranging from 0%-30%).

Conclusions  Food and Drug Administration approval should not be interpreted as suggesting equality of different manufacturers' products. Some low latex and nonlatex content gloves are very resistant to leakage and should provide an effective barrier for preventing exposure to blood-borne pathogens, while others may not.


From the University of Virginia Health System, Charlottesville.


RELATED ARTICLES

Glove Leakage Rates as a Function of Latex Content and Brand—Invited Critique
Vernon J. Henderson
Arch Surg. 2000;135(8):985.
EXTRACT | FULL TEXT  

Archives of Surgery Reader's Choice: Continuing Medical Education
Arch Surg. 2000;135(8):992-993.
FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

A Call to Ban Glove Cornstarch
Edlich and Reddy
Arch Surg 2001;136:116-116.
FULL TEXT  