You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 137 No. 2, February 2002 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (38)
 •Contact me when this article is cited
 Related Content
 •Related articles
 •Similar articles in this journal
 Topic Collections
 •Endocrine Surgery
 •Alert me on articles by topic

The Use of the Harmonic Scalpel vs Conventional Knot Tying for Vessel Ligation in Thyroid Surgery

Allan E. Siperstein, MD; Eren Berber, MD; Ebru Morkoyun

Arch Surg. 2002;137:137-142.

Hypothesis  The technique of thyroidectomy has undergone little change in several decades. The harmonic scalpel, using ultrasonic frictional heating to ligate vessels, is widely used in laparoscopic surgery, but there is little experience in open thyroidectomy. We hypothesized that the use of the harmonic scalpel could lead to a significant reduction in operative time as compared with knot tying in thyroid surgery.

Design  Retrospective case-controlled study.

Setting  Teaching institution.

Patients  One hundred seventy-one consecutive patients undergoing lobectomy or total thyroidectomy by one surgeon (A.E.S.).

Interventions  Eighty-six patients underwent thyroid surgery with the conventional clamp-and-tie technique (lobectomy, n = 49; total thyroidectomy, n = 36) and 85 with the harmonic scalpel (lobectomy, n = 38; total thyroidectomy, n = 47).

Main Outcome Measures  Demographics, pathological characteristics, thyroid size, operative time, blood loss, and complications using a 2-tailed t test, {chi}2 test, and Wilcoxon rank sum test.

Results  The 2 groups were similar regarding age and sex. There were no intraoperative complications. Mean ± SD thyroid size tended to be larger in the harmonic scalpel group for both lobectomy (5.1 ± 2.6 cm vs 4.2 ± 2.2 cm; P = .06) and total thyroidectomy specimens (6.3 ± 3.8 cm vs 4.8 ± 2.9 cm; P = .08) compared with the conventional technique. Mean ± SD operative time was shorter in the harmonic scalpel group compared with the conventional technique group for both lobectomy (89 ± 20 minutes vs 115 ± 25 minutes; P<.01) and total thyroidectomy (132 ± 39 minutes vs 161 ± 42 minutes; P<.01) procedures. There was no difference between the 2 techniques regarding the amount of blood loss for different procedures. There was no effect of tumor size on operative time (Pearson correlation factors: 0.14 for total, 0.21 for unilateral thyroidectomy).

Conclusions  The use of the harmonic scalpel for the control of thyroid vessels during thyroid surgery is safe, and it shortens the operative time by almost 30 minutes compared with the conventional technique for both unilateral lobectomy or total thyroidectomy procedures.


From the Department of General Surgery, Cleveland Clinic Foundation, Cleveland, Ohio.


RELATED ARTICLES

This Month in Archives of Surgery
Arch Surg. 2002;137(2):132.
FULL TEXT  

Archives of Surgery Reader's Choice: Continuing Medical Education
Arch Surg. 2002;137(2):229-230.
FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

LigaSure vs Clamp-and-Tie Technique to Achieve Hemostasis in Total Thyroidectomy for Benign Multinodular Goiter: A Prospective Randomized Study
Saint Marc et al.
Arch Surg 2007;142:150-156.
ABSTRACT | FULL TEXT  

LigaSure vs Clamp-and-Tie Technique to Achieve Hemostasis in Total Thyroidectomy for Benign Multinodular Goiter--Invited Critique
Prinz et al.
Arch Surg 2007;142:157-157.
FULL TEXT  

Randomized controlled trial of harmonic scalpel use during thyroidectomy.
Miccoli et al.
Arch Otolaryngol Head Neck Surg 2006;132:1069-1073.
ABSTRACT | FULL TEXT  

Evaluation of the Efficacy of the Electrosurgical Bipolar Vessel Sealer (LigaSure) Devices in Sealing Lymphatic Vessels
Novitsky et al.
SURG INNOV 2005;12:155-160.
ABSTRACT  

Use of a Diathermy System in Thyroid Surgery
Kiriakopoulos et al.
Arch Surg 2004;139:997-1000.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2002 American Medical Association. All Rights Reserved.