You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 138 No. 11, November 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Citing articles on ISI (7)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Breast Cancer
 •Surgical Oncology
 •Alert me on articles by topic

Pulse Oximeter Changes With Sentinel Lymph Node Biopsy in Breast Cancer

Mahmoud El-Tamer, MD; Ian K. Komenaka, MD; Saundra Curry, MD; Andrea B. Troxel, DSc; Beth-Ann Ditkoff, MD; Freya R. Schnabel, MD

Arch Surg. 2003;138:1257-1260.

Hypothesis  The changes reported with pulse oximetry after the injection of isosulfan blue for sentinel lymph node identification in patients with breast cancer are consistent and predictable.

Design  Retrospective study.

Setting  University hospital.

Patients and Methods  The complete anesthesia records of 92 patients who underwent sentinel lymph node biopsy with intraparenchymal injection of isosulfan blue were reviewed. The study extended from January 1999 to February 2000. The operations were all performed after the patient received general anesthesia. We injected 5 mL of isosulfan blue into the breast tissue surrounding the tumor. The data reviewed included preinjection pulse oximeter saturation readings and postinjection values continuing until the readings returned to baseline levels in the postanesthesia care unit.

Main Outcome Measures  Changes in oxygen saturation readings with the pulse oximeter before and after injection of isosulfan blue.

Results  Isosulfan blue injection interfered with pulse oximeter measurements for a substantial time—as much as 195 minutes. The mean time to the maximum change in the pulse oximeter reading was 35 minutes. The median decrease in oxygen saturation was 5%. The maximum decrease in the pulse oximeter reading was 11%.

Conclusions  Although the changes in pulse oximeter readings can be substantial, their course appears to be predictable, and therefore in most otherwise healthy patients with normal pulmonary function, invasive monitoring is not necessary.


From the Section of Breast Surgery (Drs El-Tamer, Komenaka, and Ditkoff), Department of Anesthesia (Dr Curry), Department of Biostatistics (Dr Troxel), and Department of Clinical Surgery (Dr Schnabel), Columbia-Presbyterian Medical Center, New York, NY.



THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Effect on Oximetry of Dyes Used for Sentinel Lymph Node Biopsy: Are There Differences?
Pinero et al.
Arch Surg 2004;139:1204-1207.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2003 American Medical Association. All Rights Reserved.