You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 138 No. 3, March 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (9)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Breast Cancer
 •Women's Health
 •Women's Health, Other
 •Ultrasonography
 •Alert me on articles by topic

Computer-Aided Diagnosis for 3-Dimensional Breast Ultrasonography

Dar-Ren Chen, MD; Ruey-Feng Chang, PhD; Wei-Ming Chen, MS; Woo-Kyung Moon, MD

Arch Surg. 2003;138:296-302.

Hypothesis  Using 3-dimensional (3-D) over 2-dimensional (2-D) ultrasonographic (US) images of the breast represents a potentially significant advantage for computer-aided diagnosis (CAD).

Background  Although conventional 2-D US images of the breast are increasingly used in surgical clinical practice, 3-D US imaging of the breast, a newly introduced technique, can offer more information than 2-D US images do.

Design  This study deals with a CAD method for use with the proposed 3-D US images of the breast and compares its performance with conventional 2-D US versions.

Methods  The test databases included 3-D US images of 107 benign and 54 malignant breast tumors for a total of 161 US images. All solid nodules at US belong to categories above C3 (ie, probably benign). The 3-D US imaging was performed using a scanner (Voluson 530; Kretz Technik, Zipf, Austria). New 3-D autocorrelation coefficients extended from the traditional 2-D autocorrelations were developed to extract the texture characteristics of the 3-D US images. The extracted texture features of the 3-D US images were used to classify the tumor as benign or malignant using the neural network.

Results  At the receiver operating characteristic analysis, 3-D and 2-D autocorrelation calculating schemes yielded Az values (ie, area under the receiver operating characteristic curve) of 0.97 and 0.85 in distinguishing between benign and malignant lesions, respectively. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value are statistically significantly improved using 3-D instead of 2-D US images for CAD.

Conclusions  The proposed system (for 3-D and 2-D CAD) is expected to be a useful computer-aided diagnostic tool for classifying benign and malignant tumors on ultrasonograms and can provide a second reading to help reduce misdiagnosis. Findings from this study suggest that using 3-D over 2-D US images for CAD represents a potentially significant advantage.


From the Department of General Surgery, China Medical College and Hospital, Taichung, Taiwan (Dr D.-R. Chen), and Department of Computer Science and Information Engineering, National Chung Cheng University, Chiayi, Taiwan (Drs Chang and Ms W.-M. Chen); and the Department of Diagnostic Radiology, Seoul National University Hospital, Seoul, South Korea (Dr Moon).



THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Solid Breast Masses: Neural Network Analysis of Vascular Features at Three-dimensional Power Doppler US for Benign or Malignant Classification
Chang et al.
Radiology 2007;243:56-62.
ABSTRACT | FULL TEXT  

Differentiating Benign from Malignant Solid Breast Masses: Comparison of Two-dimensional and Three-dimensional US
Cho et al.
Radiology 2006;240:26-32.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2003 American Medical Association. All Rights Reserved.