You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 141 No. 3, March 2006 TABLE OF CONTENTS
  Archives
  •  Online Features
  Operative Technique
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Citing articles on ISI (2)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Public Health
 •Obesity
 •Bariatric Surgery
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati
What's this?

Safety and Efficacy of Initial Trocar Placement in Morbidly Obese Patients

Atul K. Madan, MD; Suraj Menachery, MD

Arch Surg. 2006;141:300-303.

Hypothesis  The use of a nonbladed trocar with an optical view is a safe and effective method for initial trocar placement for laparoscopic bariatric surgery.

Design  Retrospective review of consecutive patients.

Setting  University-associated hospital.

Patients  All patients who underwent laparoscopic bariatric surgery from December 2002 to November 2003.

Intervention  Initial trocar placement.

Main Outcome Measures  Injury and bleeding during initial trocar placement, trocar placement time, and insufflation time. Trocar placement time was defined as the time to place the trocar into the peritoneal cavity (including infiltration of local anesthesia and incision). Insufflation time was defined as time to insufflate the abdomen to a pressure of 10 to 15 mm Hg (including time to place tubing on trocar).

Results  There were 228 patients who had no evidence of any bowel or vessel injury during initial trocar placement. In the last 50 patients, average body mass index (calculated as weight in kilograms divided by the square of height in meters) was 47 (range, 35-63). Average trocar placement time was 25 seconds (range, 10-60 seconds), and average insufflation time was 16 seconds (range, 5-25 seconds). In almost all cases, appropriate pneumoperitoneum was established in less than a minute. No correlation was seen between times and body mass index (trocar, P = .56; insufflation, P = .95) or waist-hip circumference (trocar, P = .74; insufflation, P=.48).

Conclusions  Initial trocar placement using a nonbladed trocar with an optical view without prior abdominal insufflation is safe and effective in morbidly obese patients. This method can be applied even in the super obese.


Author Affiliations: Minimally Invasive Surgery Section, Department of Surgery, University of Tennessee Health Science Center, Memphis.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Initial Laparoscopic Access Using an Optical Trocar Without Pneumoperitoneum Is Safe and Effective in the Morbidly Obese