 |
 |

Implementation of a Real-time Compliance Dashboard to Help Reduce SICU Ventilator-Associated Pneumonia With the Ventilator Bundle
Victor Zaydfudim, MD, MPH;
Lesly A. Dossett, MD, MPH;
John M. Starmer, MD;
Patrick G. Arbogast, PhD;
Irene D. Feurer, PhD;
Wayne A. Ray, PhD;
Addison K. May, MD;
C. Wright Pinson, MBA, MD
Arch Surg. 2009;144(7):656-662.
Background Ventilator-associated pneumonia (VAP) causes significant morbidity and mortality in critically ill surgical patients. Recent studies suggest that the success of preventive measures is dependent on compliance with ventilator bundle parameters.
Hypothesis Implementation of an electronic dashboard will improve compliance with the bundle parameters and reduce rates of VAP in our surgical intensive care unit (SICU).
Design Time series analysis of VAP rates between January 2005 and July 2008, with dashboard implementation in July 2007.
Setting Multidisciplinary SICU at a tertiary-care referral center with a stable case mix during the study period.
Patients Patients admitted to the SICU between January 2005 and July 2008.
Main Outcome Measures Infection control data were used to establish rates of VAP and total ventilator days. For the time series analysis, VAP rates were calculated as quarterly VAP events per 1000 ventilator days. Ventilator bundle compliance was analyzed after dashboard implementation. Differences between expected and observed VAP rates based on time series analysis were used to estimate the effect of intervention.
Results Average compliance with the ventilator bundle improved from 39% in August 2007 to 89% in July 2008 (P < .001). Rates of VAP decreased from a mean (SD) of 15.2 (7.0) to 9.3 (4.9) events per 1000 ventilator days after introduction of the dashboard (P = .01). Quarterly VAP rates were significantly reduced in the November 2007 through January 2008 and February through April 2008 periods (P < .05). For the August through October 2007 and May through July 2008 quarters, the observed rate reduction was not statistically significant.
Conclusions Implementation of an electronic dashboard improved compliance with ventilator bundle measures and is associated with reduced rates of VAP in our SICU.
Author Affiliations: Departments of Surgery (Drs Zaydfudim, Dossett, Feurer, May, and Pinson), Biomedical Informatics (Dr Starmer), Biostatistics (Drs Arbogast and Feurer), and Preventive Medicine (Drs Arbogast and Ray), Vanderbilt University Medical Center, Nashville, Tennessee.
CiteULike Connotea Delicious Digg Facebook Reddit Technorati Twitter
What's this?
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
Characteristics and effects of nurse dosing over-rides on computer-based intensive insulin therapy protocol performance
Campion et al.
J Am Med Inform Assoc 2011;18:251-258.
ABSTRACT
| FULL TEXT
Ventilator-Associated Pneumonia: Is Zero Possible?
Klompas
Clinical Infectious Diseases 2010;51:1123-1126.
FULL TEXT
Adherence to Ventilator-Associated Pneumonia Bundle and Incidence of Ventilator-Associated Pneumonia in the Surgical Intensive Care Unit
Bird et al.
Arch Surg 2010;145:465-470.
ABSTRACT
| FULL TEXT
Update in Community-acquired and Nosocomial Pneumonia 2009
Torres and Rello
Am. J. Respir. Crit. Care Med. 2010;181:782-787.
FULL TEXT
|