You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 142 No. 4, April 2007 TABLE OF CONTENTS
  Archives
  •  Online Features
  Paper
 This Article
 •Abstract
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Breast Cancer
 •Surgical Oncology
 •Ultrasonography
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Sonographic Hematoma-Guided vs Wire-Localized Lumpectomy for Breast Cancer

A Comparison of Margins and Volume of Resection

Rakhshanda Layeequr Rahman, MD; Elaine Iuanow, MD; Sybil Crawford, MS; Robert Quinlan, MD

Arch Surg. 2007;142:343-346.

ABSTRACT

Hypothesis  Sonographic hematoma-guided (SHG) lumpectomy achieves better margin clearance with a smaller volume of resection compared with wire-localized (WL) lumpectomy.

Design  Retrospective study.

Setting  University Comprehensive Breast Center.

Patients  Consecutive patients treated over 6 months at the breast center with stereotactic biopsy–proven cancers that were not visualized on ultrasonography. The SHG and WL techniques were compared.

Main Outcome Measures  The matching variables were age, mammographic abnormality, tumor size and type, and lymph node status. The outcome variables were the closest margin of resection, volume of resection, resection index (resection volume divided by tumor volume), and rate of margin revision.

Results  Twenty-nine patients had SHG lumpectomy and 34 had WL lumpectomy. The SHG and WL groups were similar in age, mammographic abnormality, tumor size and type, and lymph node status. The median (interquartile range) closest margin was 5.0 (5-8) mm in the SHG group vs 3.5 (1-7) mm in the WL group (P = .01). The median (interquartile range) resection volume was 85.0 (60-128) cm3 in the SHG group vs 143.4 (54-229) cm3 in the WL group (P = .048). The median (interquartile range) resection index was 77.1 (51-220) in the SHG group vs 315.9 (89-3025) in the WL group (P = .003). The margin was revised in 1 (3.4%) of the patients who underwent SHG lumpectomy vs 5 (14.7%) of the patients who underwent WL lumpectomy (P = .20).

Conclusions  Sonographic hematoma-guided lumpectomy is superior to WL lumpectomy in obtaining adequate margins while minimizing the volume of resection.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References
 •Discussion

Screening mammography and advanced imaging techniques have increased the rate of detection of nonpalpable cancers in the breast that are amenable to conservation therapy. The goal of breast conservation in the treatment of cancer is to achieve an oncologic resection with adequate margins while maintaining cosmesis. This poses significant challenges in the case of nonpalpable lesions and requires image-guided localization to effect resection. The current standard technique of operative guidance is preoperative wire localization (WL), which is associated with several limitations. First, the ideal entry site for the radiologist is often distant from the ideal incision site for the surgeon. Second, surgeons depend on 2-dimensional postlocalization radiographs to estimate the 3-dimensional position of the lesion in relation to the wire, which results in positive margins in up to 62% of patients.1-3 Third, up to 10% of patients have vasovagal episodes during wire placement.4-5 Fourth, complications such as wire transection6 and displacement have been described.7-8 Last but not least are the logistic issues that arise between surgical and radiological scheduling systems.

These disadvantages have led to the quest for better alternatives to WL. Intraoperative ultrasonography has proven to be superior to WL in all of the aforementioned aspects for lesions that are visible on ultrasonography.9-12 Unfortunately, 60% to 70% of mammographic lesions are not visible on ultrasonography and the onus of acceptable oncoplastic resection continues to fall on WL.

Smith et al13 described the use of the sonographically visible hematoma (induced iatrogenically by stereotactic biopsy) as a localizing device with intraoperative ultrasonography. Postbiopsy hematoma is a naturally occurring localizing device that is visible on ultrasonography without the need for another invasive procedure. We hypothesized that sonographic hematoma-guided (SHG) lumpectomy for breast cancer effects better resection margins by providing all dimensions of the lesion and results in better cosmetic outcome by ensuring a lower volume of resection.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References
 •Discussion

PATIENTS

Sixty-three consecutive patients treated with breast conservation at the Comprehensive Breast Center between October 1, 2005, and March 31, 2006, for stereotactic biopsy–proven small unifocal cancers that were not visualized on ultrasonography were studied. Patients with extensive lesions requiring bracketing wires were excluded. UMass Memorial Health Center, Worcester, Mass, is a university-based practice that has a multispecialty-based Comprehensive Breast Center with 3 breast surgeons. Two surgeons (R.M.Q. and Anne Larkin, MD) use WL for lumpectomies and 1 surgeon (R.L.R.) performs SHG resection for breast cancer. The rest of the management protocols are similar across the entire practice.

SHG EXCISION TECHNIQUE

This technique involves using the iatrogenic hematoma as a localization device that is created during stereotactic biopsy of the mammographic lesion. Patients are evaluated in the office within 7 to 10 days of biopsy, where the sonographic visibility of the hematoma is documented by the surgeon with a focused ultrasonographic scan of the breast using triangulation based on the mammographic results. Surgery is performed ideally within 4 to 5 weeks of biopsy, lest the hematoma resolves. An intraoperative ultrasonographic scan of the documented area is performed by the surgeon, and skin markings are made at the site of hematoma as well as at a 1-cm margin from the edge to affect ultrasonography-guided excision. Specimen ultrasonography is performed to document the presence of the hematoma with adequate margins. Suspected close margins can be revised as additional shaved margins during the same surgery. The specimen is oriented and submitted for pathological analysis.

DATA COLLECTION

Data were collected from the medical records regarding patient age, mammographic abnormality, tumor size and type, and lymph node status for matching between the 2 groups. The closest margin, the volume of resection, the need for reexcision, and the cosmetic outcome score by the patient using a visual analog scale of 0 to 10 were recorded as outcome variables.

STATISTICAL ANALYSIS

Microsoft Excel software (Microsoft Corp, Redmond, Wash) was used to record the data. The differences in age, mammographic abnormality, tumor type, and tumor size were computed for matching between the WL and SHG groups. The tumor volume and the volume of resection were calculated from the 3 dimensions of the tumor and the specimen described in all of the reports of the pathological analysis; the resection index was computed as a ratio of resection volume and tumor volume such that the lower the index is, the better the cosmetic resection is. SigmaStat software version 2.0 (SPSS, Inc, Chicago, Ill) was used for statistical significance.


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References
 •Discussion

Sixty-three patients were treated for stereotactically diagnosed nonpalpable breast cancer that was not visible on ultrasonography during the study period. Thirty-four patients (54.0%) underwent WL lumpectomy and 29 (46.0%) were subjected to SHG resection. The 2 groups were similar in age, mammographic abnormality, and tumor characteristics (Table 1). The tumor volume was larger in the SHG group with borderline statistical significance (P = .07). The comparison of outcome variables between the 2 groups is depicted in Table 2. The median (interquartile range) closest margin was 5.0 (5-8) mm in the SHG group vs 3.5 (1-7) mm in the WL group (P = .01). The volume of resection was significantly larger in the WL group (median, 143.4 cm3) despite the smaller volume of the tumor. The median (interquartile range) resection index was 77.1 (51-220) in the SHG group vs 315.9 (89-3025) in the WL group (P = .003). The median (interquartile range) cosmetic outcome score was 6 (5-8) for the patients in WL group vs 9 (7-9) for the patients in the SHG group (P = .03). Only 1 patient (3.4%) needed margin revision in the SHG group as compared with 5 patients (14.7%) in the WL group who needed margin revision; however, this difference was not statistically significant (P = .20).


View this table:
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Table 1. Comparison of Baseline Characteristics Between Wire-Localized and Sonographic Hematoma-Guided Lumpectomy Groups



View this table:
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Table 2. Comparison of Main Outcome Measures Between Wire-Localized and Sonographic Hematoma-Guided Lumpectomy Groups



COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References
 •Discussion

The ideal localization procedure for nonpalpable breast cancers would provide precise identification of the site of the lesion with adequate intraoperative assessment of margins such that the rate of reexcision is limited and the cosmetic outcome is acceptable. In addition, it would be painless and convenient for patients and would not hamper the surgical scheduling. The current standard of WL falls short on these criteria1-9; hence, the pursuit to develop alternative methods continues. The SHG technique is an immense improvement over WL to meet the mentioned criteria.

First, the hematoma is a natural result of biopsy, thereby completely obviating the need for another localization procedure. This eliminates the patient's inconvenience associated with an invasive procedure without anesthesia, pain, and vasovagal episodes. Second, the position of the hematoma within the breast is always at the site of the lesion compared with the wire, which is placed at an approximated close location. This issue is further complicated in situations where the original lesion is completely excised during the biopsy and the wire is placed using the clip as a guide. Clip migration occurs in about half of the cases,14-15 adding to the challenge of localization. These factors are probably responsible for the high rate of positive margins after WL lumpectomy. Our data show the positive margin rate in the WL group to be 15%, which is much lower than that reported in the literature.16 In this group, clip migration occurred in only 3 patients and was not associated with positive margins. Although in this study both techniques had comparable margin clearance, the volume of resection was significantly larger in the WL group, which in turn may have contributed to the lower cosmetic outcome score. It is established that cosmetic outcome worsens as the resection volume increases.17 Taylor et al18 found that the resection volume of 100 cm3 is associated with cosmetic compromise irrespective of breast size. Our data show that SHG lumpectomy achieved good margins with a much smaller volume of resection compared with WL (median resection volume, 85.0 cm3 vs 143.4 cm3, respectively). Third, sonographic assessment in the operating room provides appropriate assessment of all margins to plan excision, and specimen ultrasonography can guide immediately if a margin revision is indicated.13 In our study, 2 margins were revised intraoperatively based on specimen ultrasonography. Finally, from a logistic standpoint, SHG excision obviates the need for radiology scheduling; moreover, specimen ultrasonography is much faster than specimen radiography, thereby enhancing efficiency in the operating room. Admittedly, the SHG technique is not without problems. There is a learning curve involved in the use of ultrasonography technology by the surgeons. In addition, localization is not possible if the diagnosis is established by fine-needle aspiration and may be compromised if the biopsy is associated with significant hemorrhage causing a large hematoma or if multiple needle insertions are performed. However, it is becoming increasingly clear that ultrasonography has become an indispensable tool for the breast surgeon in the office and the operating room setting. Several studies have shown the accuracy and convenience of surgeon-based breast ultrasonography19; our study demonstrates the effect of surgeon-performed intraoperative ultrasonography on the quality of breast cancer treatment in terms of adequate excision, patient friendliness, and cosmetic superiority with an added value of obviating the logistics of scheduling.

Other techniques for nonpalpable lesions involve radioisotope-guided excision with technetium Tc 99m–labeled colloid injection20-21 or radioactive seed placement.22 Although both of these approaches achieve better margins and superior cosmetic outcome, they have certain shortcomings. First, an extra procedure is required for localization after the diagnosis of cancer or a high-risk lesion is established. Scheduling issues between 2 departments are curtailed but still exist. Shine-through radioactivity can potentially compromise the sentinel node procedure in the case of technetium Tc 99m use, and the Compton effect has to be considered with the use of radioactivity. Last but not least, exposure to radioactivity is eventually going to limit the use of the procedure. With the current Occupational Safety and Health Administration guidelines23 and radioactivity exposure to the surgeons by the sentinel node biopsy procedure,24 surgeons can perform about 100 procedures per year; adding another procedure with radioactivity exposure is likely to limit the number of procedures each surgeon can perform per year without exceeding the recommended dose.

In conclusion, we believe that SHG resection for nonpalpable breast cancer is a simple, convenient (for patients and surgeons), and accurate technique for localization that ensures adequate margins while keeping the resection volume to a minimum.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References
 •Discussion

Correspondence: Rakhshanda Layeequr Rahman, MD, Department of Surgery, UMass Memorial Health Care, 119 Belmont St, Worcester, MA 01605 (layeequr{at}ummhc.org).

Accepted for Publication: November 1, 2006.

Author Contributions: Study concept and design: Layeequr Rahman and Quinlan. Acquisition of data: Layeequr Rahman and Iuanow. Analysis and interpretation of data: Layeequr Rahman and Crawford. Drafting of the manuscript: Layeequr Rahman. Critical revision of the manuscript for important intellectual content: Layeequr Rahman, Iuanow, Crawford, and Quinlan. Statistical analysis: Crawford. Administrative, technical, and material support: Layeequr Rahman and Iuanow. Study supervision: Quinlan.

Financial Disclosure: None reported.

Previous Presentation: This paper was presented at the 87th Annual Meeting of the New England Surgical Society; September 16, 2006; Groton, Conn; and is published after peer review and revision. The discussions that follow this article are based on the originally submitted manuscript and not the revised manuscript.

Author Affiliations: Departments of Surgery (Drs Layeequr Rahman and Quinlan), Radiology (Dr Iuanow), and Behavioral Sciences (Ms Crawford), UMass Memorial Health Care, Worcester, Mass.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References
 •Discussion

1. Acosta JA, Greenlee JA. Surgical margins after needle localization breast biopsy. Am J Surg. 1995;170:643-645. FULL TEXT | ISI | PUBMED
2. Kaufman CS, Delbecq R, Jacobson L. Excising the reexcision: stereotactic core biopsy decreases the need for reexcision of breast cancer. World J Surg. 1998;22:1023-1028. FULL TEXT | ISI | PUBMED
3. Cangiarella J, Groos J, Symmans WF; et al. The incidence of positive margins with breast conserving therapy following mammotome biopsy for microcalcification. J Surg Oncol. 2000;74:263-266. FULL TEXT | ISI | PUBMED
4. Rissanen TJ, Makarainen HP, Mattila SI; et al. Wire localized biopsy of breast lesions: a review of 425 cases found in screening or clinical mammography. Clin Radiol. 1993;47:14-22. FULL TEXT | ISI | PUBMED
5. Helvie MA, Ikeda DM, Adler DD. Localization and needle aspiration of breast lesions: complications in 370 cases. AJR Am J Roentgenol. 1991;157:711-714. FREE FULL TEXT
6. Homer MJ. Transection of the localization hooked wire during breast biopsy. AJR Am J Roentgenol. 1983;141:929-930. FREE FULL TEXT
7. Bristol JB, Jones PA. Transgression of localizing wire into the pleural cavity prior to mammography. Br J Radiol. 1981;54:139-140. FREE FULL TEXT
8. Davis PS, Wexhsler RJ, Feig SA; et al. Migration of breast biopsy localization wire. AJR Am J Roentgenol. 1988;150:787-788. FREE FULL TEXT
9. Snider HC Jr, Morrison DG. Intraoperative ultrasound localization of nonpalpable breast lesions. Ann Surg Oncol. 1999;6:308-314. FULL TEXT | ISI | PUBMED
10. Rahusen FD, Taets van Amerongen AH, van Diest PJ, Borgstein PJ, Bleichrodt RP, Meijer S. Ultrasound-guided lumpectomy of nonpalpable breast cancer: a feasibility study looking at the accuracy of obtained margins. J Surg Oncol. 1999;72:72-76. FULL TEXT | ISI | PUBMED
11. Harlow SP, Krag DN, Ames SE, Weaver DL. Intraoperative ultrasound localization to guide surgical excision of nonpalpable breast carcinoma. J Am Coll Surg. 1999;189:241-246. FULL TEXT | ISI | PUBMED
12. Rahusen FD, Bremers AJ, Fabry HF, van Amerongen AH, Boom RP, Meijer S. Ultrasound-guided lumpectomy of nonpalpable breast cancer vs wire-guided resection: a randomized clinical trial. Ann Surg Oncol. 2002;9:994-998. FULL TEXT | ISI | PUBMED
13. Smith LF, Henry-Tillman R, Rubio IT, Korourian S, Klimberg VS. Intraoperative localization after stereotactic biopsy without a needle. Am J Surg. 2001;182:584-589. FULL TEXT | ISI | PUBMED
14. Kass R, Klimberg VS, Kass L; et al. Clip migration in stereotactic biopsy. Am J Surg. 2002;184:325-331. FULL TEXT | ISI | PUBMED
15. Esserman LE, Cura MA, DaCosta D. Recognizing pitfalls in early and late migration of clip markers after image-guided directional vacuum-assisted biopsy. Radiographics. 2004;24:147-156. FREE FULL TEXT
16. Nurko J, Mancino AT, Whitacre E, Edwards MJ. Surgical benefits conveyed by biopsy site marking system using ultrasound localization. Am J Surg. 2005;190:618-622. FULL TEXT | ISI | PUBMED
17. Audisio RA, Nadeem R, Thind R, Harris O, Desmond S, Chagla LS. Radioguided occult lesion localization (ROLL) for non-palpable breast lesions: the localization method of choice is now available in UK. Ann R Coll Surg Engl. 2005;87:92-95. FULL TEXT | ISI | PUBMED
18. Taylor ME, Perez CA, Halverson KJ; et al. Factors influencing cosmetic results after conservation therapy for breast cancer. Int J Radiat Oncol Biol Phys. 1995;31:753-764. FULL TEXT | ISI | PUBMED
19. Fine RE, Staren ED. Updates in breast ultrasound. Surg Clin North Am. 2004;84:1001-1034. FULL TEXT | ISI | PUBMED
20. Paganelli G, Veronesi U. Innovation in early breast cancer surgery: radio-guided occult lesion localization and sentinel node biopsy. Nucl Med Commun. 2002;23:625-627. FULL TEXT | ISI | PUBMED
21. Paganelli G, Luini A, Veronesi U. Radioguided occult lesion localization (ROLL) in breast cancer: maximizing efficacy, minimizing mutilation. Ann Oncol. 2002;13:1839-1840. FREE FULL TEXT
22. Gray RJ, Pockaj BA, Karstaedt PJ, Roarke MC. Radioactive seed localization of nonpalpable breast lesions is better than wire localization. Am J Surg. 2004;188:377-380. FULL TEXT | ISI | PUBMED
23. Occupational Safety and Health Administration. Ionizing radiation. In: Toxic and Hazardous Substances. Washington, DC: Occupational Safety & Health Administration; 1998:1-9.
24. De Kanter AY, Arends PP, Eggermont AMM; et al. Radiation protection for the sentinel node procedure in breast cancer. Eur J Surg Oncol. 2003;29:396-399. FULL TEXT | ISI | PUBMED



Discussion

Richard Wait, MD, Springfield, Mass: Would there be any advantage to doing an ultrasound-guided needle localization so that you have something solid in there when you are cutting down vs just making some lines on the skin, which may move around afterwards?

Dr Layeequr Rahman: I think it is a learning curve and comfort zone issue. Many surgeons would put a wire in to be able to feel something within the breast, but I think the wire is a thin structure so localization is good, but margins, still I would rely on staying 1 cm based on my image because the wire will not give me an idea about that.

Scott Kurtzman, MD, Waterbury, Conn: Do you use any oncoplastic techniques, because the difference in volume resected may not be important if you know how to put things back together again. Ultrasound in the OR [operating room] may be out of the reach of many surgeons.

Dr Layeequr Rahman: When we have to, if the volume of resection has to be high, we do employ oncoplastic techniques, but I think the idea would be you do not want to resect the tissue if you do not have to for a margin's sake but yes, of course, if you are bound to from an oncologic standpoint, then you would employ techniques to do that.

David W. Butsch, MD, Montpelier, Vt: I enjoyed the paper. I wonder, is it the same surgeon doing a wire localization as is doing the hematoma localization?

Dr Layeequr Rahman: No.

Dr Butsch: That might influence the results, do you think?

Dr Layeequr Rahman: Yes. That is why I looked at some matching variables, but yes, that bias we cannot remove.

Dr Butsch: Dr Quinlan was doing the wire ones, wasn't he?

Dr Layeequr Rahman: Yes.

Financial Disclosure: None reported.