You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 100 No. 1, January 1970 TABLE OF CONTENTS
  Archives
  •  Online Features
  ARTICLES
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (35)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Physiological Basis for the Systemic-to-Coronary Artery Bypass Graft

Inadequacy of the Internal Mammary Artery for This Purpose and Appraisal of the Ascending Aorta as Its Proximal Site

Akio Wakabayashi, MD; Edward Beron, MD; Mary A. Lou, MD; John Y. Mino, MD; Iseu A. da Costa, MD; John E. Connolly, MD

AMA Arch Surg. 1970;100(1):17-19.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

Since Murray et al1 reported the feasibility of a systemicto-coronary artery bypass in 1954, many articles have appeared which have described surgical techniques to anastomose the internal mammary artery to the anterior descending or circumflex branch of the left coronary artery by means of nonsuture techniques,2 temporary internal shunts,3 vascular anastomosing staplers,4 or extracorporeal circulation.5 These technical contributions were aimed to improve the patency rate of the coronary artery anastomosis without reference to the physiological background of the coronary circulation.

Coronary bypass inflow is determined by the vascular resistance of the coronary arterial system and the pressure gradient across the anastomosis. If the coronary vascular resistance is constant, the pressure gradient will determine the inflow. It is known that pulsatile pressure contours change as they propagate along the aorta.6 There is also a time lag of pulse wave propagation between the aortic root and . . . [Full Text PDF of this Article]


Author Affiliations

Irvine, Calif

From the Department of Surgery, University of California, Irvine.


Footnotes

Submitted for publication Aug 20, 1969.

Reprint requests to Department of Surgery, University of California, Irvine, Calif 92664 (Dr. Connolly).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1970 American Medical Association. All Rights Reserved.