You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 95 No. 5, November 1967 TABLE OF CONTENTS
  Archives
  •  Online Features
  ARTICLES
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

U-Shaped Mechanical Auxiliary Ventricle

Toru Okura, MD; Steinar Tjønneland, MD; P. S. Freed, MS Bio-Eng; Adrian Kantrowitz, MD

AMA Arch Surg. 1967;95(5):821-825.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

IN 1966, the implantation of a mechanical auxiliary ventricle in two patients gave evidence that the prosthesis may be feasible as a permanent circulatory-assist device in patients with intractable left ventricular failure.1,2 In this paper modifications of the U-shaped ventricle and results of animal experiments are described.

Materials and Methods

The implantable components of the mechanical ventricle consist of a flexible Dacron-reinforced silicone rubber pumping chamber, an outer casing with an air tube, and myocardial electrodes; the external components include a supply of compressed air, a solenoid valve, and an electronic synchronizing device.3 In the experiments reported here, the following modifications of this system were employed:

1. A one-piece housing of resin-coated fiber glass covered with silicone rubber (Fig 1).

2. An improved implantation technique in dogs that facilitates transection of the aortic arch between the two anastomoses.

3. An applanation pressure transducer which can be fitted over . . . [Full Text PDF of this Article]


Author Affiliations

Brooklyn, NY

From the departments of Surgery, Maimonides Medical Center and State University of New York Downstate Medical Center, Brooklyn, NY.


Footnotes

Submitted for publication June 18, 1967.

Read before the 15th Scientific Meeting of the North American Chapter of the International Cardiovascular Society, Atlantic City, NJ, June 17, 1967.

Reprint requests to Maimonides Medical Center, 4802 Tenth Ave, Brooklyn, NY 11219 (Dr. Kantrowitz).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1967 American Medical Association. All Rights Reserved.